Make sure the meter is turned off. If you insert the cable while the meter is already on, the meter will not respond to computer commands. Interface Cable 4 Transfer data Follow the instructions provided with the diabetes management software product to download the results from the meter.

You will not be able to perform a test when the meter is in communication mode. Make sure your meter, test strips, and control solution are at room temperature before testing. Do Not apply control solution to the skin or eyes as it may cause irritation. How to test with control solution Start with the meter off. If you have turned the meter on to change settings or review past results, turn it off. Do Not bend the test strip. You must mark the test before you apply control solution.

Once you have completed the test, you cannot change the marking. The meter is now ready to perform a control solution test. Remove the cap and squeeze the vial to discard the first drop. Then wipe the tip with a clean tissue or cloth. Hold the vial upside down and gently squeeze a hanging drop. Make sure the confirmation window fills completely.

The control solution results can be viewed in the list of past results, but are not counted in your result averages. Each vial of test strips may have a different control solution range. If the results you get are not within this range, the meter and test strips may not be working properly. Repeat the control solution test. It is not a recommended range for your blood glucose level. Replacement batteries can be found in most stores where batteries are sold.

Your meter comes with two batteries already installed— one that powers the meter only and one that powers the backlight.

Meter battery Backlight battery Low meter battery The meter shows a battery icon in the upper right corner of the display or a low battery message to indicate the condition of the meter battery only. When the battery icon first appears, there is enough power for a minimum of more tests. You should replace the meter battery as soon as possible.

You must install a new battery before using your meter. Low backlight battery Replace the backlight battery when you can no longer see the backlight coming on. There will not be any icon on the meter display to indicate a low backlight battery. Note that the meter will provide accurate blood glucose results even when the backlight battery needs to be replaced.

Open the battery door and pull up on the battery ribbon. The white ribbon is for the meter battery, and the black ribbon is for the backlight battery. Push the battery until it snaps into the battery clasp. Insert the two battery door tabs into the matching holes on the meter, and push down until you hear the door click into place.

If the meter still does not power on, contact LifeScan Customer Service at 1 7 days a week, 8 a. However, you may need to re-set your meter settings. See Setting the meter language, date and time in Section 2.

Dispose of batteries according to your local environmental regulations. Storing your system Store your meter, test strips, control solution and other items in your carrying case after each use. Keep all items away from direct sunlight and heat. Store test strips only in their original vial. Checking for expiration or damage to test strips and control solution Expiration dates for test strips and control solutions are printed on their vial labels. When you first open a new vial of test strips or control solution, record the discard date on the label.

Refer to the test strip or control solution vial for instructions on determining the discard date. Cleaning your meter To clean your meter, wipe the outside with a soft cloth dampened with water and mild detergent.

Do Not use alcohol or another solvent to clean your meter. Do Not get any liquids, dirt, dust, blood, or control solution inside the meter through the test port or the data port. Never spray cleaning solution on the meter or immerse it in any liquid. Cleaning your lancing device and clear cap To clean these items, wipe them with a soft cloth dampened with water and mild detergent. Do Not immerse the lancing device in any liquid. To disinfect these items, prepare a solution of one part household bleach to nine parts water.

Wipe the lancing device with a soft cloth dampened with this solution. Immerse the caps only in this solution for 30 minutes. After disinfecting, rinse briefly with water and allow both to air dry.

Messages do not appear in all cases when a problem has occurred. Improper use may cause an inaccurate result without producing an error message. Although this message could be due to a test error, it is safer to treat first and then do another test.

Re-check your glucose level. Wait a few minutes and insert a new test strip. There is a problem with the meter. Do Not use the meter. Error message could be caused either by a used test strip or a problem with the meter. Repeat the test with a new test strip; see Section 3, Testing your blood glucose.

The sample was applied before the meter was ready. Repeat the test with a new test strip. There may be a problem with the test strip. For example, it may have been damaged or moved during testing. The sample was improperly applied. There may be a problem with the meter. The meter has detected a problem with the test strip. Possible causes are test strip damage or an incompletely filled confirmation window. Refer to information on blood application see Section 3, Testing your blood glucose or control solution testing see Section 6, Control solution testing.

Meter battery is low but still has enough power to perform a test. Test results will still be accurate, but replace the battery as soon as possible. Meter battery does not have enough power to perform a test. Replace meter battery. This result will not be included in result averages. You can still perform a blood glucose test and get an accurate result. Eastern Time to report this occurrence, unless this is your first use of the meter.

Your meter was unable to recall this result. You can still perform a blood glucose test and get an accurate result, but contact LifeScan Customer Service at 1 7 days a week, 8 a. Eastern Time to report this occurrence.

This helps you and your health care professional to compare your meter results with laboratory tests. However, your meter result may differ from your laboratory result due to normal variation.

Meter results can be affected by factors and conditions that do not affect laboratory results in the same way. For accuracy and precision data and for important information on limitations, see the insert that comes with your test strips. Sacks, D. Philadelphia: W. Page 28 Message What it means What to do The sample was applied before the meter Repeat the test with a new test strip.

One of the following may apply: You may have high glucose and have If you tested in a cool environment, repeat This helps you and your health care professional to compare your meter results with laboratory tests. The guarantee extends only to the original purchaser and is not transferable. Print page 1 Print document 31 pages. Rename the bookmark. Delete bookmark? Cancel Delete.

Delete from my manuals? Sign In OR. Don't have an account? Sign up! Restore password. Upload manual. Upload from disk. Upload from URL. All coded instruction and program statements contained herein is, and remains copyrighted works and confidential proprietary information of Seagate Technology LLC or its affiliates.

Any use, derivation, dissemination, reproduction, or any attempt to modify, reproduce, distribute, disclose copyrighted material of Seagate Technology LLC, for any reason, in any manner, medium, or form, in whole or in part, if not expressly authorized, is strictly prohibited. Seagate reserves the right to change, without notice, product offerings or specifications.